At Broadline NSN, our aim is to help customers meet their operational requirements by supplying an extensive inventory of items that are available for procurement. On this page, you can explore a catalog of high-demand parts that are organized under the NSN 5905-00-539-4900, a unique identifier for products that are exceptionally popular. This includes top-requested part numbers like JU5031 SD30560PTI0N2, JA1N056F503UA, S240-1044P9, 40100-503, RV4NAY3D503A, and numerous others, and you always have the option to pinpoint desired parts using our search engine and filters. We are the only independent distributor that operates with a NO CHINA SOURCING pledge, meaning that every item is sourced from a trusted NSN parts supplier on our Approved Vendor List (AVL).
As soon as you come across an item of interest, do not hesitate to submit a quote request by simply clicking on the “RFQ” button situated next to any offering. When completing an RFQ form, we ask that you include desired delivery dates and target price points, among other pertinent details about your needs for NSN 5905-00-539-4900. Within 15 minutes or less of submission, one of our industry experts will reach out with a customized quote that features competitive pricing and convenient shipping options. Get started today and see how we can serve as your strategic sourcing partner!
Item Name | Resistor Variable Nonwire Wound |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 00-539-4900 (005394900) |
NCB Code | USA (00) |
Manufacturer | Rockwell Automation Ltd, Raytheon Company, Hickok Incorporated, Military Specifications, Lockheed Martin Corporation, Rohde And Schwarz Inc, Heico Ohmite Llc, Lucent Technologies Inc, Engineered Electric Company, L 3 Communications Corporation, Aeronautical Communications, National Weather Service, Clarostat Sensors And Controls, Thales Defense And Security Inc, Rockwell Collins Aerospace, Contel Information Systems Inc, Miller Electric Mfg Co, Tektronix Gmbh |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
JU5031 SD30560PTI0N2 | rockwell automation ltd | resistor variable nonwire wound | RFQ |
JA1N056F503UA | rockwell automation ltd | resistor variable nonwire wound | RFQ |
S240-1044P9 | raytheon company | resistor variable nonwire wound | RFQ |
40100-503 | hickok incorporated | resistor variable nonwire wound | RFQ |
RV4NAY3D503A | military specifications | resistor variable nonwire wound | RFQ |
RV4NAY5D503A | military specifications | resistor variable nonwire wound | RFQ |
7700535PT425 | lockheed martin corporation | resistor variable nonwire wound | RFQ |
240-1210P17 | raytheon company | resistor variable nonwire wound | RFQ |
517853 | rohde and schwarz inc | resistor variable nonwire wound | RFQ |
31727 | rockwell automation ltd | resistor variable nonwire wound | RFQ |
J38253F | rockwell automation ltd | resistor variable nonwire wound | RFQ |
7768146P4 | lockheed martin corporation | resistor variable nonwire wound | RFQ |
RV4NAYSD503A | heico ohmite llc | resistor variable nonwire wound | RFQ |
8516088 | lucent technologies inc | resistor variable nonwire wound | RFQ |
S125-387 | engineered electric company | resistor variable nonwire wound | RFQ |
240-1211P17 | raytheon company | resistor variable nonwire wound | RFQ |
G-1135 | l 3 communications corporation | resistor variable nonwire wound | RFQ |
A7244 | aeronautical communications | resistor variable nonwire wound | RFQ |
K211R1127 | national weather service | resistor variable nonwire wound | RFQ |
53C3-50K | clarostat sensors and controls | resistor variable nonwire wound | RFQ |
RV4ATSC503A | military specifications | resistor variable nonwire wound | RFQ |
RV4AYSD503A | military specifications | resistor variable nonwire wound | RFQ |
RV4ATSA503A | thales defense and security inc | resistor variable nonwire wound | RFQ |
JA1N100D503UA | military specifications | resistor variable nonwire wound | RFQ |
380-1343-000 | rockwell collins aerospace | resistor variable nonwire wound | RFQ |
416039-14 | raytheon company | resistor variable nonwire wound | RFQ |
MILR94-5 | military specifications | resistor variable nonwire wound | RFQ |
RV4NAYSD503A | military specifications | resistor variable nonwire wound | RFQ |
RV4NAYSD-503A | contel information systems inc | resistor variable nonwire wound | RFQ |
JA1N048S503MA | rockwell automation ltd | resistor variable nonwire wound | RFQ |
030-131 | miller electric mfg co | resistor variable nonwire wound | RFQ |
JU5031 SD30560PTI0N2 | clarostat sensors and controls | resistor variable nonwire wound | RFQ |
JAN048S503UE | rockwell automation ltd | resistor variable nonwire wound | RFQ |
J69658 | rockwell automation ltd | resistor variable nonwire wound | RFQ |
311-023 | tektronix gmbh | resistor variable nonwire wound | RFQ |
5021-181 | raytheon company | resistor variable nonwire wound | RFQ |
719110-002 | raytheon company | resistor variable nonwire wound | RFQ |
JA1N200P503UA | rockwell automation ltd | resistor variable nonwire wound | RFQ |
RV4NAYSD-503A | rockwell automation ltd | resistor variable nonwire wound | RFQ |
864548-0503 | thales defense and security inc | resistor variable nonwire wound | RFQ |
JA2N100F503UA | rockwell automation ltd | resistor variable nonwire wound | RFQ |
240-1316P18 | raytheon company | resistor variable nonwire wound | RFQ |
RV4NAXSD503A | military specifications | resistor variable nonwire wound | RFQ |
JA1N056S503VA | rockwell automation ltd | resistor variable nonwire wound | RFQ |
380-503K | clarostat sensors and controls | resistor variable nonwire wound | RFQ |
RV4NAYSD503B | military specifications | resistor variable nonwire wound | RFQ |
J38253E | rockwell automation ltd | resistor variable nonwire wound | RFQ |
MIL-PRF-94/5 | military specifications | resistor variable nonwire wound | RFQ |
311-0023-00 | tektronix gmbh | resistor variable nonwire wound | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 11 |
AAQL | BODY STYLE | CYLINDRICAL BUSHING MOUNTEDCYLINDRICAL BUSHING MOUNTED |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 1.312 INCHES MINIMUM AND 1.312 INCHES MINIMUM AND 1.562 INCHES MAXIMUM1.562 INCHES MAXIMUM |
ABPM | BODY DIAMETER | 1.032 INCHES MINIMUM AND 1.032 INCHES MINIMUM AND 1.156 INCHES MAXIMUM1.156 INCHES MAXIMUM |
ABWV | SHAFT DIAMETER | 0.248 INCHES MINIMUM AND 0.248 INCHES MINIMUM AND 0.251 INCHES MAXIMUM0.251 INCHES MAXIMUM |
ABXF | SHAFT LENGTH | 0.844 INCHES MINIMUM AND 0.844 INCHES MINIMUM AND 0.906 INCHES MAXIMUM0.906 INCHES MAXIMUM |
ADAP | MOUNTING BUSHING LENGTH | 0.344 INCHES MINIMUM AND 0.344 INCHES MINIMUM AND 0.390 INCHES MAXIMUM0.390 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.468 INCHES MINIMUM AND 0.468 INCHES MINIMUM AND 0.656 INCHES MAXIMUM0.656 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 1.515 INCHES MAXIMUM1.515 INCHES MAXIMUM |
AEDX | SHAFT STYLE | ROUND,SLOTTEDROUND,SLOTTED |
AEFD | ACTUATOR TYPE | SINGLE SHAFTSINGLE SHAFT |
AEFK | MAXIMUM STARTING TORQUE | 6.00 INCH-OUNCES6.00 INCH-OUNCES |
AEFM | MAXIMUM STOP TORQUE | 128.00 INCH-OUNCES128.00 INCH-OUNCES |
AEFP | NONTURN DEVICE RADIUS | 0.515 INCHES MINIMUM AND 0.515 INCHES MINIMUM AND 0.547 INCHES MAXIMUM0.547 INCHES MAXIMUM |
AJYN | SCREW THREAD DIAMETER | 0.375 INCHES NOMINAL0.375 INCHES NOMINAL |
AJYP | SCREW THREAD SERIES DESIGNATOR | UNEFUNEF |
AJYQ | SCREW THREAD QUANTITY PER INCH | 32.032.0 |
AXGY | MOUNTING METHOD | STANDARD BUSHINGSTANDARD BUSHING |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 50.0 KILOHMS SINGLE SECTION50.0 KILOHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 309.0 MINIMUM AND 309.0 MINIMUM AND 320.0 MAXIMUM320.0 MAXIMUM |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 120.0 SINGLE SECTION120.0 SINGLE SECTION |
CQPH | DEVICE DESIGN TYPE | NONTURN AT 9 OCLOCKNONTURN AT 9 OCLOCK |
CQTM | TERMINAL LOCATION | RADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCERADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 2.0 FREE AIR SINGLE SECTION2.0 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION-10.0 TO 10.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPSSTOPS |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION70.0 SINGLE SECTION |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-94 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTING |
TTQY | TERMINAL TYPE AND QUANTITY | 3 TAB,SOLDER LUG3 TAB,SOLDER LUG |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-94/5 GOVERNMENT SPECIFICATION81349-MIL-R-94/5 GOVERNMENT SPECIFICATION |
Relevant Components for NSN - 5905-00-539-4900, 5905005394900 | ||||
5998-01-299-7568 (5998012997568) | 5995-01-025-2810 (5995010252810) | 5935-00-758-4675 (5935007584675) | 5930-00-994-3493 (5930009943493) | |
5970-01-393-9445 (5970013939445) | 5998-01-395-9776 (5998013959776) | 5999-01-562-8757 (5999015628757) | 5930-01-119-8055 (5930011198055) | |
5905-00-630-9486 (5905006309486) | 5999-01-368-0617 (5999013680617) | 5950-01-334-2987 (5950013342987) | 5930-01-699-5936 (5930016995936) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote