At Broadline NSN, our aim is to help customers meet their operational requirements by supplying an extensive inventory of items that are available for procurement. On this page, you can explore a catalog of high-demand parts that are organized under the NSN 5915-01-155-7759, a unique identifier for products that are exceptionally popular. This includes top-requested part numbers like RF7814B, RF07814B, 52-339-005, 930463-2B, FN959, and numerous others, and you always have the option to pinpoint desired parts using our search engine and filters. We are the only independent distributor that operates with a NO CHINA SOURCING pledge, meaning that every item is sourced from a trusted NSN parts supplier on our Approved Vendor List (AVL).
As soon as you come across an item of interest, do not hesitate to submit a quote request by simply clicking on the “RFQ” button situated next to any offering. When completing an RFQ form, we ask that you include desired delivery dates and target price points, among other pertinent details about your needs for NSN 5915-01-155-7759. Within 15 minutes or less of submission, one of our industry experts will reach out with a customized quote that features competitive pricing and convenient shipping options. Get started today and see how we can serve as your strategic sourcing partner!
Item Name | Filter Radio Frequency Interfere |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5915 Filters and Networks |
National Item Identification Number (NIIN) | 01-155-7759 (011557759) |
NCB Code | USA (01) |
Manufacturer | Ems Development Corporation, Spectrum Control Inc, Raytheon Company, Filtronetics Inc |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
RF7814B | ems development corporation | filter radio frequency interfere | RFQ |
RF07814B | ems development corporation | filter radio frequency interfere | RFQ |
52-339-005 | spectrum control inc | filter radio frequency interfere | RFQ |
930463-2B | raytheon company | filter radio frequency interfere | RFQ |
FN959 | filtronetics inc | filter radio frequency interfere | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 9.800 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 9.190 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.270 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.940 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.271 INCHES MINIMUM AND 0.278 INCHES MAXIMUM |
AFGA | OPERATING TEMP RANGE | -55.0 TO 90.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 6.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 6.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 6.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 4TH RADIO INTERFERENCE 1ST FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 5TH RADIO INTERFERENCE 2ND FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 6TH RADIO INTERFERENCE 3RD FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHCG | MAXIMUM TEMP RISE | 35.0 DEG CELSIUS |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE 1ST FUNCTION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE 2ND FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES |
CTJS | UNPACKAGED UNIT WEIGHT | 8.500 POUNDS NOMINAL |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
Relevant Components for NSN - 5915-01-155-7759, 5915011557759 | ||||
5935-00-686-9723 (5935006869723) | 5930-00-977-3532 (5930009773532) | 5935-01-290-9312 (5935012909312) | 5935-00-843-2459 (5935008432459) | |
5962-01-353-6603 (5962013536603) | 5910-01-092-4997 (5910010924997) | 5999-01-380-6788 (5999013806788) | 5940-01-344-7201 (5940013447201) | |
5963-00-237-3843 (5963002373843) | 5950-00-903-7719 (5950009037719) | 5935-01-065-7983 (5935010657983) | 5998-01-542-4319 (5998015424319) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote