At Broadline NSN, our aim is to help customers meet their operational requirements by supplying an extensive inventory of items that are available for procurement. On this page, you can explore a catalog of high-demand parts that are organized under the NSN 5950-00-497-8949, a unique identifier for products that are exceptionally popular. This includes top-requested part numbers like 2006, 17-13045-1, and numerous others, and you always have the option to pinpoint desired parts using our search engine and filters. We are the only independent distributor that operates with a NO CHINA SOURCING pledge, meaning that every item is sourced from a trusted NSN parts supplier on our Approved Vendor List (AVL).
As soon as you come across an item of interest, do not hesitate to submit a quote request by simply clicking on the “RFQ” button situated next to any offering. When completing an RFQ form, we ask that you include desired delivery dates and target price points, among other pertinent details about your needs for NSN 5950-00-497-8949. Within 15 minutes or less of submission, one of our industry experts will reach out with a customized quote that features competitive pricing and convenient shipping options. Get started today and see how we can serve as your strategic sourcing partner!
Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 00-497-8949 (004978949) |
NCB Code | USA (00) |
Manufacturer | Dyco Electronics Inc, Textron Systems Corporation, Lockheed Martin Corporation |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
2006 | dyco electronics inc | transformer power | RFQ |
17-13045-1 | textron systems corporation | transformer power | RFQ |
17-13045-1 | lockheed martin corporation | transformer power | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.109 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.734 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.766 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.625 INCHES MINIMUM AND 2.750 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.250 INCHES MINIMUM AND 2.375 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.624 INCHES MINIMUM AND 3.812 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 450.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY12.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 12.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY56.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY46.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 56.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; SIX SECONDARY WINDINGS,ALL SECONDARY VOLTAGE AND CURRENT IS AFTER RECTIFICATION |
TEST | TEST DATA DOCUMENT | 80070-17-13045 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 24 SOLDER STUD |
Relevant Components for NSN - 5950-00-497-8949, 5950004978949 | ||||
5998-01-299-7568 (5998012997568) | 5995-01-025-2810 (5995010252810) | 5935-00-758-4675 (5935007584675) | 5930-00-994-3493 (5930009943493) | |
5970-01-393-9445 (5970013939445) | 5998-01-395-9776 (5998013959776) | 5999-01-562-8757 (5999015628757) | 5930-01-119-8055 (5930011198055) | |
5905-00-630-9486 (5905006309486) | 5999-01-368-0617 (5999013680617) | 5950-01-334-2987 (5950013342987) | 5930-01-699-5936 (5930016995936) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote