At Broadline NSN, our aim is to help customers meet their operational requirements by supplying an extensive inventory of items that are available for procurement. On this page, you can explore a catalog of high-demand parts that are organized under the NSN 5950-01-339-8204, a unique identifier for products that are exceptionally popular. This includes top-requested part numbers like 321-18050-05, 12020-1, 10132963, 984882-5B, and numerous others, and you always have the option to pinpoint desired parts using our search engine and filters. We are the only independent distributor that operates with a NO CHINA SOURCING pledge, meaning that every item is sourced from a trusted NSN parts supplier on our Approved Vendor List (AVL).
As soon as you come across an item of interest, do not hesitate to submit a quote request by simply clicking on the “RFQ” button situated next to any offering. When completing an RFQ form, we ask that you include desired delivery dates and target price points, among other pertinent details about your needs for NSN 5950-01-339-8204. Within 15 minutes or less of submission, one of our industry experts will reach out with a customized quote that features competitive pricing and convenient shipping options. Get started today and see how we can serve as your strategic sourcing partner!
Item Name | Transformer Assembly |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 01-339-8204 (013398204) |
NCB Code | USA (01) |
Manufacturer | Oeco Corp, Sora Power Inc, Nimikkeistokeskus Ncb Finland, Raytheon Company |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 3.570 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.187 INCHES NOMINAL 1ST GROUP |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 2ND COMPONENT |
ADAT | BODY WIDTH | 3.440 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.500 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
AXGY | MOUNTING METHOD | SLOT 1ST GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE 2ND GROUP |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 3RD SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 4 SECONDARY 1ST COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 3RD COMPONENT AND 3 SECONDARY 3RD COMPONENT |
CBBL | FEATURES PROVIDED | W/RECTIFIER |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES AC NOMINAL 2ND COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 35.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.090 2ND COMPONENT 4TH SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.100 3RD COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT SINGLE PRIMARY |
CRMJ | WINDING POWER RATING | 0.2 VOLTS-AMPERES 3RD COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 18.03 VOLTS-AMPERES 2ND COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 3535.0 VOLTS-AMPERES 2ND COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 530.25 AC VOLTS NOMINAL 1ST COMPONENT 4TH SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.2 AMPERES DC NOMINAL 3RD COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.280 2ND COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 130.00 DC VOLTS MINIMUM 3RD COMPONENT 2ND SECONDARY AND 137.00 DC VOLTS MAXIMUM 3RD COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.55 AC VOLTS NOMINAL 3RD COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 16.26 AC VOLTS NOMINAL 3RD COMPONENT 1ST SECONDARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 5.375 INCHES NOMINAL 3RD MOUNTING FACILITY SINGLE CENTER GROUP |
AFHM | MOUNTING TAB WIDTH | 0.625 INCHES NOMINAL |
AXGY | MOUNTING METHOD | TAB 3RD GROUP |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 1.200 2ND COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 2.750 1ST COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 5245.8 VOLTS-AMPERES 2ND COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 70.70 AC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 36 WIRE LEAD |
CWJS | WINDING OPERATING VOLTAGE | 6.01 AC VOLTS NOMINAL 2ND COMPONENT 4TH SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 6.030 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.500 INCHES NOMINAL 2ND GROUP |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL ALL COMPONENTS |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 3RD COMPONENT AND INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL 3RD COMPONENT |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 4.500 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 2 2ND GROUP |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT 4TH SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 1ST SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT AND 4 SECONDARY 2ND COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.01 AMPERES AC NOMINAL 3RD COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 0.035 AMPERES AC NOMINAL 3RD COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES AC NOMINAL 1ST COMPONENT 4TH SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.040 3RD COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.060 1ST COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 12.000 2ND COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 159.07 VOLTS-AMPERES 1ST COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 160.2 VOLTS-AMPERES 3RD COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 300.5 VOLTS-AMPERES 2ND COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 7.47 VOLTS-AMPERES 3RD COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 14.14 AC VOLTS NOMINAL 2ND COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 149.88 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.55 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 178.16 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY AND 195.84 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY AND 213.57 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.01 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY |
Relevant Components for NSN - 5950-01-339-8204, 5950013398204 | ||||
5998-01-299-7568 (5998012997568) | 5995-01-025-2810 (5995010252810) | 5935-00-758-4675 (5935007584675) | 5930-00-994-3493 (5930009943493) | |
5970-01-393-9445 (5970013939445) | 5998-01-395-9776 (5998013959776) | 5999-01-562-8757 (5999015628757) | 5930-01-119-8055 (5930011198055) | |
5905-00-630-9486 (5905006309486) | 5999-01-368-0617 (5999013680617) | 5950-01-334-2987 (5950013342987) | 5930-01-699-5936 (5930016995936) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote