When you require Transformer Power components such as part number 005108 with the NSN 5950003940289 for your operations, Broadline NSN is your best bet. Whether you are searching for parts from manufacturers like Berkshire Transformer or something else, our team is dedicated to helping you acquire what you need with competitive rates and rapid lead times for your benefit. As such, when you have discovered items of interest, we encourage you to take advantage of our rapid RFQ service by filling out and submitting the form featured throughout our website. On this form, be sure to include relevant details such as your desired part quantity and budget parameters so that our dedicated team members can craft a customized solution that suits your particular operational needs.
Note : We Will Not Share Your Information To Any Third Parties.
At Broadline NSN, we are dedicated to distributing reliable products such as those with the NSN 5950-00-394-0289 or CAGE code 89870. As an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited parts distributor, you can rely on the caliber of our offerings which feature more than 2 billion new, used, obsolete, and hard-to-find components that are readily available for your purchase at any time. Countless products are subject to rigorous quality control measures to guarantee their fit, form, and function prior to your purchase for your benefit, and all come from leading manufactures like Berkshire Transformer. Those looking for high-quality parts like listings belonging to the FSC 5950 Coils and Transformers can count on our team to get them what they need in rapid time. Call or email us with any questions and we will be more than happy to assist you through any stage of the procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-394-0289 Item PartTypeName: TRANSFORMER,POWER | 5950 | 003940289 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
005108 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT400.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.562 INCHES MAXIMUM3.562 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.062 INCHES MAXIMUM3.062 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 4.875 INCHES MAXIMUM4.875 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 80.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALEDHERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT4 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.8 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 320.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 320.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY13.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY33.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY13.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 33.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 33.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 10 TURRET |