When you require Circuitbreaker components such as part number TQD32200WL TQD225S with the NSN 5925008799567 for your operations, Broadline NSN is your best bet. Whether you are searching for parts from manufacturers like General Electric Company or something else, our team is dedicated to helping you acquire what you need with competitive rates and rapid lead times for your benefit. As such, when you have discovered items of interest, we encourage you to take advantage of our rapid RFQ service by filling out and submitting the form featured throughout our website. On this form, be sure to include relevant details such as your desired part quantity and budget parameters so that our dedicated team members can craft a customized solution that suits your particular operational needs.
Note : We Will Not Share Your Information To Any Third Parties.
At Broadline NSN, we are dedicated to distributing reliable products such as those with the NSN 5925-00-879-9567 or CAGE code 60969. As an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited parts distributor, you can rely on the caliber of our offerings which feature more than 2 billion new, used, obsolete, and hard-to-find components that are readily available for your purchase at any time. Countless products are subject to rigorous quality control measures to guarantee their fit, form, and function prior to your purchase for your benefit, and all come from leading manufactures like General Electric Company. Those looking for high-quality parts like listings belonging to the FSC 5925 Circuit Breakers can count on our team to get them what they need in rapid time. Call or email us with any questions and we will be more than happy to assist you through any stage of the procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-879-9567 Item PartTypeName: CIRCUIT BREAKER | 5925 | 008799567 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
CCS200 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ADAT | BODY WIDTH | 4.125 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.594 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 6.250 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE,DOUBLE THROW |
AJEC | BOSS HEIGHT | 0.219 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS AND TIME DELAY ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
CRTK | SWITCH TERMINAL TYPE | WIRE LEAD |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 240.0 AC |
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 6.562 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.375 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.880 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.375 INCHES NOMINAL |
AKPX | POLE QUANTITY | 3 |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 200.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 10000.0 AC ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE THREE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 75.000 MINIMUM AT 200 PCT AND 325.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 225.0 AC |
CWJK | CASE MATERIAL | PLASTIC |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |