When you require Transformer Power components such as part number C2115 with the NSN 5950003769596 for your operations, Broadline NSN is your best bet. Whether you are searching for parts from manufacturers like Jetronic Industries Inc or something else, our team is dedicated to helping you acquire what you need with competitive rates and rapid lead times for your benefit. As such, when you have discovered items of interest, we encourage you to take advantage of our rapid RFQ service by filling out and submitting the form featured throughout our website. On this form, be sure to include relevant details such as your desired part quantity and budget parameters so that our dedicated team members can craft a customized solution that suits your particular operational needs.
Note : We Will Not Share Your Information To Any Third Parties.
At Broadline NSN, we are dedicated to distributing reliable products such as those with the NSN 5950-00-376-9596 or CAGE code 91820. As an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited parts distributor, you can rely on the caliber of our offerings which feature more than 2 billion new, used, obsolete, and hard-to-find components that are readily available for your purchase at any time. Countless products are subject to rigorous quality control measures to guarantee their fit, form, and function prior to your purchase for your benefit, and all come from leading manufactures like Jetronic Industries Inc. Those looking for high-quality parts like listings belonging to the FSC 5950 Coils and Transformers can count on our team to get them what they need in rapid time. Call or email us with any questions and we will be more than happy to assist you through any stage of the procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-376-9596 Item PartTypeName: TRANSFORMER,POWER | 5950 | 003769596 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
32-2115B | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.000 INCHES NOMINAL3.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.469 INCHES NOMINAL2.469 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.844 INCHES NOMINAL2.844 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALEDHERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT3 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP32 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP0.138 INCHES SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 130.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 365.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 545.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 780.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 130.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY365.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 545.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 780.00 AC V |
CWJS | WINDING OPERATING VOLTAGE | 130.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY365.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 545.00 AC VOLTS NO |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 12 STANDOFF,SOLDER LUG |