When you require Cable Specificationial Purpose Electrical components such as part number 80216 with the NSN 6145014071696 for your operations, Broadline NSN is your best bet. Whether you are searching for parts from manufacturers like South Bay Cable Corp or something else, our team is dedicated to helping you acquire what you need with competitive rates and rapid lead times for your benefit. As such, when you have discovered items of interest, we encourage you to take advantage of our rapid RFQ service by filling out and submitting the form featured throughout our website. On this form, be sure to include relevant details such as your desired part quantity and budget parameters so that our dedicated team members can craft a customized solution that suits your particular operational needs.
Note : We Will Not Share Your Information To Any Third Parties.
At Broadline NSN, we are dedicated to distributing reliable products such as those with the NSN 6145-01-407-1696 or CAGE code 51173. As an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited parts distributor, you can rely on the caliber of our offerings which feature more than 2 billion new, used, obsolete, and hard-to-find components that are readily available for your purchase at any time. Countless products are subject to rigorous quality control measures to guarantee their fit, form, and function prior to your purchase for your benefit, and all come from leading manufactures like South Bay Cable Corp. Those looking for high-quality parts like listings belonging to the FSC 6145 Wire and Cable Electrical can count on our team to get them what they need in rapid time. Call or email us with any questions and we will be more than happy to assist you through any stage of the procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6145-01-407-1696 Item PartTypeName: CABLE,SPECIAL PURPOSE,ELECTRICAL | 6145 | 014071696 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
80216 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 4TH POSITION TAPE ALL GROUPS |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
MATT | Material | PLASTIC POLYURETHANE 6TH POSITION JACKET CABLE |
MATT | Material | COPPER 2ND POSITION SHIELD BRAID, METALLIC SECOND CONDUCTOR |
SFTT | Surface Treatment | TIN 2ND POSITION SHIELD BRAID, METALLIC SECOND CONDUCTOR |
SFTT | Surface Treatment | TIN 3RD POSITION SHIELD BRAID, METALLIC THIRD GROUP |
CXCW | Conductor Form | STRANDED SINGLE CONDUCTOR |
MATT | Material | COPPER 5TH POSITION SHIELD BRAID, METALLIC THIRD GROUP |
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 3RD POSITION TAPE SECOND CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION SIXTH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 7TH CONDUCTOR |
AMQN | Conductor Quantity | 9 |
HUES | Color | BROWN 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 6TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 8TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 5TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 2ND CONDUCTOR |
HUES | Color | GREEN 1ST POSITION PRIMARY INSULATION SIXTH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 3RD CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 9TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 4TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 1ST CONDUCTOR |
HUES | Color | ORANGE 1ST POSITION PRIMARY INSULATION NINTH CONDUCTOR |
HUES | Color | BLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
AAGR | Cross-Sectional Shape Style | ROUND |
CXDC | Round Conductor Size | 16 AWG 4TH CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 5TH CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 9TH CONDUCTOR |
HUES | Color | GREEN 1ST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR |
CXDC | Round Conductor Size | 22 AWG 1ST CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 7TH CONDUCTOR |
MRC | Decoded Requirement | Clear Text Reply |
CXDG | Strand Awg Size Per Conductor | 26 9TH CONDUCTOR |
ABJH | Temp Rating | -28.0 DEG CELSIUS AND 65.0 DEG CELSIUS |
CXDG | Strand Awg Size Per Conductor | 29 5TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 26 7TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 3RD CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 3RD CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 6TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 30 1ST CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 6TH CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 8TH CONDUCTOR |
CXDT | Group Quantity | 4 |
MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
CXFG | Conductor Sequence Within Groups | FIRST CONDUCTOR FIRST GROUP AND SECOND CONDUCTOR FIRST GROUP |
CXFG | Conductor Sequence Within Groups | SEVENTH CONDUCTOR FOURTH GROUP AND EIGHTH CONDUCTOR FOURTH GROUP AND NINTH CONDUCTOR FOURTH GROUP |
CXDC | Round Conductor Size | 22 AWG 2ND CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 26 8TH CONDUCTOR |
MATT | Material | COPPER 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR |
HUES | Color | RED 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 4TH CONDUCTOR |
SFTT | Surface Treatment | TIN 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR |
HUES | Color | WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
SFTT | Surface Treatment | TIN CORE CONDUCTOR ALL CONDUCTORS |
CXDG | Strand Awg Size Per Conductor | 30 2ND CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 3RD POSITION TAPE FIRST CONDUCTOR |
HUES | Color | YELLOW 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTOR |
HUES | Color | YELLOW 1ST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
CXDQ | Conductor Arrangement And Quantity | 2 SINGLES AND 2 TWISTED PAIR AND 1 TRIPLES |
CXFG | Conductor Sequence Within Groups | FIFTH CONDUCTOR THIRD GROUP AND SIXTH CONDUCTOR THIRD GROUP |
CXFG | Conductor Sequence Within Groups | THIRD CONDUCTOR SECOND GROUP AND FOURTH CONDUCTOR SECOND GROUP |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION NINTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
ADVL | Cross Section Outside Diameter | 0.665 INCHES NOMINAL |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote